Use this directory to identify the first official contact route for a commercial dock or door project. It is a small reference table, not a permit determination: describe the building address, whether work is repair or replacement, and every associated structural, electrical, operator, restraint, or opening change to the authority.
Direct findings
- The building address controls the starting authority. A mailing city, contractor territory, or equipment brand does not establish jurisdiction.
- Winnebago County publishes shared building services for Cherry Valley, Durand, New Milford, Rockton, Roscoe, South Beloit, and unincorporated Winnebago County. Communities absent from that published list are marked for confirmation rather than assigned an invented office.
- Rockford's FAQ describes a narrow exemption for a door or window replacement when size is unchanged and no fire rating is required. It is not a universal test for dock equipment, operators, electrical work, structural changes, or associated work.
- Illinois energy provisions can enter a replacement or installation review, but the applicable provisions and exceptions depend on the project. This site does not publish a door R-value or U-factor.
- OSHA regulations, agency enforcement documents, consensus standards, product standards, and trade-association sheets are different kinds of documents. The index preserves those distinctions, and facility safety personnel decide workplace applicability.
Permit-authority directory
Start with the row matching the facility location, then use the official source to confirm the authority before authorizing work. “Verified” means the reviewed source supports the authority relationship shown; it does not mean a permit is required. “Source linked” provides an official contact route without claiming the office. “Confirm with authority” marks a gap in the reviewed source set.
| Community or jurisdiction | Actual authority and contact route | Official source | Agency phone (reference only) | Relevant scope note | Verification status and date |
|---|---|---|---|---|---|
| RockfordAddress inside the City of Rockford | City of RockfordCity permits overview | PermitsCity of Rockford, Illinois | Not published in the reviewed source | Ask whether the complete dock or door scope requires review. The City's limited same-size door replacement exemption is not a universal permit test. | VerifiedChecked 2026-09-15 |
| Loves ParkConfirm authority from the building address | Authority not verifiedConfirm with the community; use the County page to check whether County service applies | Building DivisionWinnebago County Community Development | Not published in the reviewed source | Loves Park is not on the County page's published community list. Do not assume City or County handling. | Confirm with authorityChecked 2026-09-15 |
| Machesney ParkConfirm authority from the building address | Authority not verifiedConfirm with the community; use the County page to check whether County service applies | Building DivisionWinnebago County Community Development | Not published in the reviewed source | Machesney Park is not on the County page's published community list. Confirm the current permit route before planning work. | Confirm with authorityChecked 2026-09-15 |
| Cherry ValleyCommunity listed by the County Building Division | Winnebago County Community Development, Building DivisionCounty Building Division page | Building DivisionWinnebago County Community Development | Not published in the reviewed source | Confirm the parcel and the complete dock, door, structural, and electrical scope with the County. | VerifiedChecked 2026-09-15 |
| New MilfordCommunity listed by the County Building Division | Winnebago County Community Development, Building DivisionCounty Building Division page | Building DivisionWinnebago County Community Development | Not published in the reviewed source | Confirm whether repair, replacement, or associated work needs County review. | VerifiedChecked 2026-09-15 |
| RoscoeCommunity listed by the County Building Division | Winnebago County Community Development, Building DivisionCounty Building Division page | Building DivisionWinnebago County Community Development | Not published in the reviewed source | Use the facility address and full equipment scope when asking the County what review applies. | VerifiedChecked 2026-09-15 |
| RocktonCommunity listed by the County Building Division | Winnebago County Community Development, Building DivisionCounty Building Division page | Building DivisionWinnebago County Community Development | Not published in the reviewed source | Confirm the authority's treatment of the full project rather than relying on the name of the equipment. | VerifiedChecked 2026-09-15 |
| South BeloitCommunity listed by the County Building Division | Winnebago County Community Development, Building DivisionCounty Building Division page | Building DivisionWinnebago County Community Development | Not published in the reviewed source | Confirm permit and inspection questions for the specific address and proposed scope. | VerifiedChecked 2026-09-15 |
| WinnebagoConfirm authority from the building address | Authority not verifiedConfirm with the community; use the County page to check whether County service applies | Building DivisionWinnebago County Community Development | Not published in the reviewed source | The Village of Winnebago is not on the County page's published community list. Confirm the current route. | Confirm with authorityChecked 2026-09-15 |
| PecatonicaConfirm authority from the building address | Authority not verifiedConfirm with the community; use the County page to check whether County service applies | Building DivisionWinnebago County Community Development | Not published in the reviewed source | Pecatonica is not on the County page's published community list. Confirm the permitting office. | Confirm with authorityChecked 2026-09-15 |
| DurandCommunity listed by the County Building Division | Winnebago County Community Development, Building DivisionCounty Building Division page | Building DivisionWinnebago County Community Development | Not published in the reviewed source | Confirm review for the specific building and all associated work with the County. | VerifiedChecked 2026-09-15 |
| Unincorporated Winnebago CountyUnincorporated County address | Winnebago County Community Development, Building DivisionCounty Building Division page | Building DivisionWinnebago County Community Development | Not published in the reviewed source | The County page expressly lists unincorporated Winnebago County; confirm the parcel and project scope. | VerifiedChecked 2026-09-15 |
| BelvidereAddress inside the City of Belvidere | City of Belvidere Building DepartmentCity Building Department page | Building DepartmentCity of Belvidere, Illinois | Not published in the reviewed source | The City identifies its permitting and inspection role. Ask about the proposed dock or door work. | VerifiedChecked 2026-09-15 |
| Poplar GroveConfirm the current building or code-enforcement contact | Authority not verifiedVillage contact page | Contact the VillageVillage of Poplar Grove, Illinois | Not published in the reviewed source | Do not assume Boone County handles Village permits; ask the Village to identify the current office. | Source linkedChecked 2026-09-15 |
| CapronConfirm authority from the building address | Authority not verifiedConfirm directly with the community or Boone County | Contact the VillageVillage of Poplar Grove, Illinois | Not published in the reviewed source | No Capron or Boone County permitting office was verified in the reviewed source set. The linked Boone-area municipal contact does not establish jurisdiction. | Confirm with authorityNo substantive source check |
| Unincorporated Boone CountyConfirm authority for the parcel | Authority not verifiedConfirm directly with Boone County | Building DepartmentCity of Belvidere, Illinois | Not published in the reviewed source | The linked City page establishes only Belvidere's role and does not establish County jurisdiction. A broader County office was not verified. | Confirm with authorityNo substantive source check |
Manufacturing statistics by state
For a separate, non-commercial research asset, see the July 2026 manufacturing statistics by state. It includes all 50 states, job-count and employment-share rankings, annual change, methodology checks, source links, and versioned downloads.
High lift vs vertical lift
For a separate, non-commercial comparison of headroom, backroom, lift limits, operators, and source conflicts, see the high lift vs vertical lift headroom data. It includes worked examples, strict comparison tables, source notes, and versioned CSV and JSON downloads.
Illinois layers
Local authority is only one layer of project review. The Illinois Capital Development Board identifies the amended 2024 IECC, effective November 30, 2025, under 71 Ill. Adm. Code 600 as the Illinois Energy Conservation Code. Applicability, exceptions, and project timing are specific to the work; this reference does not state a required door R-value or U-factor and does not claim that the code requires seals.
| Layer | What the reviewed record supports | Project decision | Official source |
|---|---|---|---|
| Energy code | Amended 2024 IECC, effective November 30, 2025, under 71 Ill. Adm. Code 600 | Confirm applicability, exceptions, and timing for the proposed opening and associated work. | Illinois Capital Development Board energy-code page |
| Prevailing wage | No project-specific applicability statement was verified. | Do not treat silence as confirmation that the layer applies or does not apply; obtain project-specific guidance for public work. | Not published as a verified claim |
| Licensing summary | A broader Illinois or local licensing summary has not been verified. | Ask the provider for documentation required by the facility and confirm project requirements with the issuing authority. | Not published as a verified claim |
Technical reference index
This index helps a maintenance manager distinguish documents that may be raised during equipment, safety, or opening-protective review. An entry is not a statement that the document applies to every dock. OSHA regulations are not consensus standards, and OSHA's restraint directive and motor-carrier interpretation are not standalone regulations. Applicability belongs with the employer's responsible safety personnel and the appropriate authority.
| Document | Issuing organization | Document type | Narrow relevance | Official source | Checked date |
|---|---|---|---|---|---|
| 29 CFR 1910.26 — Dockboards | U.S. Occupational Safety and Health Administration | regulation | Dockboard capacity, securing against movement, and placement; a dock plate is not a leveler. | 29 CFR 1910.26 — Dockboards | 2026-09-15 |
| 29 CFR 1910.28 — Duty to have fall protection and falling object protection | U.S. Occupational Safety and Health Administration | regulation | Index entry for a facility-specific review of open dock-edge fall exposure; no requirement is paraphrased here. | 29 CFR 1910.28 — Duty to have fall protection and falling object protection | Catalog only |
| 29 CFR 1910.147 — The control of hazardous energy (lockout/tagout) | U.S. Occupational Safety and Health Administration | regulation | Hazardous-energy control during machine servicing; not a complete pit-entry procedure. | 29 CFR 1910.147 — The control of hazardous energy (lockout/tagout) | 2026-09-15 |
| 29 CFR 1910.176 — Handling materials, general | U.S. Occupational Safety and Health Administration | regulation | Catalog entry for aisles, clearances, and storage in materials-handling areas; no requirement is paraphrased here. | 29 CFR 1910.176 — Handling materials, general | Catalog only |
| 29 CFR 1910.178 — Powered industrial trucks | U.S. Occupational Safety and Health Administration | regulation | Powered trucks entering trailers and securing trailers against movement; scope differs from the directive and interpretation. | 29 CFR 1910.178 — Powered industrial trucks | 2026-09-15 |
| STD 01-11-007 — Mechanical means of restraint for trailers at loading docks | U.S. Occupational Safety and Health Administration | agency directive | Enforcement guidance on mechanical restraints as a means of securing trailers; not a standalone regulation. | STD 01-11-007 — Mechanical means of restraint for trailers at loading docks | 2026-09-15 |
| Standard interpretation, March 7, 2011 — motor carrier / loading dock enforcement | U.S. Occupational Safety and Health Administration | agency interpretation | Enforcement limits involving motor carriers and loading dock operations; facility applicability remains case-specific. | Standard interpretation, March 7, 2011 — motor carrier / loading dock enforcement | 2026-09-15 |
| ANSI MH30.1 — Performance and Testing of Dock Leveling Devices | ANSI / Material Handling Industry (MHI) | consensus standard | Catalog entry for the industry standard for dock leveling devices; contents were not read or paraphrased. | ANSI MH30.1 — Performance and Testing of Dock Leveling Devices | Catalog only |
| ANSI MH30.3 — Performance and Testing of Vehicle Restraining Devices | ANSI / Material Handling Industry (MHI) | consensus standard | Catalog entry for the industry standard for vehicle restraining devices; contents were not read or paraphrased. | ANSI MH30.3 — Performance and Testing of Vehicle Restraining Devices | Catalog only |
| NFPA 80 — Standard for Fire Doors and Other Opening Protectives | National Fire Protection Association | consensus standard | Catalog entry for fire-door inspection, testing, and maintenance; edition, interval, and local adoption are not asserted. | NFPA 80 — Standard for Fire Doors and Other Opening Protectives | Catalog only |
| UL 325 — Standard for Door, Drapery, Gate, Louver, and Window Operators and Systems | UL Standards & Engagement | consensus standard | Catalog entry for the product safety standard for door operators and entrapment protection; contents were not read. | UL 325 — Standard for Door, Drapery, Gate, Louver, and Window Operators and Systems | Catalog only |
| DASMA Technical Data Sheets | Door & Access Systems Manufacturers Association | industry technical sheet | Catalog entry for the trade-association technical sheet library for doors and dock equipment; individual sheets were not read. | DASMA Technical Data Sheets | Catalog only |
Definitions and method
Issuing authority
The government office that accepts, reviews, or directs permit questions for the project address. Shared services can make that a county office even when the mailing address names a village. The directory reports only relationships supported by the reviewed sources.
Same-size replacement
On this page, this phrase refers only to the City of Rockford FAQ's limited door/window replacement language: size unchanged and no required fire rating. It does not decide whether changes to an operator, wiring, framing, leveler, restraint, pit, or other associated work require review.
Fire-rated assembly
An opening protective whose label and function are part of the building's fire-protection approach. This reference does not identify the rating, adopted edition, testing interval, or required service for a particular opening. Preserve labels and confirm the assembly with the authority and a capable provider.
Field-level verification
Confirmation using the actual address, equipment identity, labels, drawings when available, and full proposed scope. Directory status cannot replace this step because municipal boundaries, parcel conditions, and associated work can change the answer.
Index entry vs verified requirement
An index entry records an official title or catalog link and its narrow subject. It does not paraphrase inaccessible text or establish local adoption. A verified substantive requirement is narrower: the linked text was opened and supports the statement made. Even then, project-level applicability is not decided here.
Source selection
The directory favors official city, village, county, state, federal, standards-issuer, and trade-association pages. It does not use contractor pages or competitor summaries to assign jurisdiction or paraphrase standards. Where the reviewed official set did not identify an office, the row says to confirm instead of filling the gap.
Updates
Substantive pages opened during this review carry the date 2026-09-15. “Catalog only” means the official title or directory was indexed but its contents were not read. A null date in the CSV preserves that distinction. Contact routes and authority arrangements should be rechecked before each project.
Limitations
This page is not a permit, code opinion, legal opinion, safety-training program, repair procedure, or project-compliance determination. It does not establish fees, inspection timing, approval, provider credentials, or whether any cited document applies to a specific employer or opening. Agency phone numbers appear only when the number was verified in the reviewed source record; none met that publication rule in this edition.
For planned equipment changes, review the loading dock equipment installation and replacement page. For commercial repair request scope, return to the Rockford loading dock repair homepage.
Directory rows published: 16. Each row keeps its own verification status and checked date.
Need a repair or installation instead of a reference?
Call to describe the commercial equipment, problem, and building address. A third-party provider confirms whether it can help and discusses scope, availability, pricing, and terms directly with you.
Calls to the number on this site may be routed to a third-party loading dock and door service provider for review. The provider — not this website — confirms whether it can take the job, when it can be there, what it will charge, and on what terms. This website does not perform repairs, employ technicians, stock parts, or guarantee that a provider is available.
Sources
Official documents consulted for this page. A source link supports the specific statement it is cited for, not every sentence on the page. Confirm current requirements with the issuing authority.
- City of Rockford, Illinois: Construction & Development Services FAQChecked
- City of Rockford, Illinois: PermitsChecked
- City of Rockford, Illinois: Building PermitsReference only
- City of Rockford, Illinois: Forms & ApplicationsReference only
- Winnebago County Community Development: Building DivisionChecked
- City of Belvidere, Illinois: Building DepartmentChecked
- Village of Poplar Grove, Illinois: Contact the VillageChecked
- Illinois Capital Development Board: Illinois Energy Conservation CodeChecked
- U.S. Occupational Safety and Health Administration: 29 CFR Part 1910 — Occupational Safety and Health StandardsChecked
- U.S. Occupational Safety and Health Administration: STD 01-11-007 — Mechanical means of restraint for trailers at loading docksChecked
- U.S. Occupational Safety and Health Administration: Standard interpretation, March 7, 2011 — motor carrier / loading dock enforcementChecked