The building address determines which authority reviews loading dock work, and several Rockford-area communities share county building services. This reference lists official permit contacts, Illinois code layers, and the technical standards a facility or provider may be asked about.

Call(815) 401-4418

Independent service-request website. Calls may be shared with a third-party provider, which confirms availability, pricing, and service terms.

Checked

Use this directory to identify the first official contact route for a commercial dock or door project. It is a small reference table, not a permit determination: describe the building address, whether work is repair or replacement, and every associated structural, electrical, operator, restraint, or opening change to the authority.

Direct findings

  1. The building address controls the starting authority. A mailing city, contractor territory, or equipment brand does not establish jurisdiction.
  2. Winnebago County publishes shared building services for Cherry Valley, Durand, New Milford, Rockton, Roscoe, South Beloit, and unincorporated Winnebago County. Communities absent from that published list are marked for confirmation rather than assigned an invented office.
  3. Rockford's FAQ describes a narrow exemption for a door or window replacement when size is unchanged and no fire rating is required. It is not a universal test for dock equipment, operators, electrical work, structural changes, or associated work.
  4. Illinois energy provisions can enter a replacement or installation review, but the applicable provisions and exceptions depend on the project. This site does not publish a door R-value or U-factor.
  5. OSHA regulations, agency enforcement documents, consensus standards, product standards, and trade-association sheets are different kinds of documents. The index preserves those distinctions, and facility safety personnel decide workplace applicability.

Permit-authority directory

Start with the row matching the facility location, then use the official source to confirm the authority before authorizing work. “Verified” means the reviewed source supports the authority relationship shown; it does not mean a permit is required. “Source linked” provides an official contact route without claiming the office. “Confirm with authority” marks a gap in the reviewed source set.

Download CSV

Northern Illinois dock permit-authority directory
Community or jurisdictionActual authority and contact routeOfficial sourceAgency phone (reference only)Relevant scope noteVerification status and date
RockfordAddress inside the City of RockfordCity of RockfordCity permits overviewPermitsCity of Rockford, IllinoisNot published in the reviewed sourceAsk whether the complete dock or door scope requires review. The City's limited same-size door replacement exemption is not a universal permit test.VerifiedChecked 2026-09-15
Loves ParkConfirm authority from the building addressAuthority not verifiedConfirm with the community; use the County page to check whether County service appliesBuilding DivisionWinnebago County Community DevelopmentNot published in the reviewed sourceLoves Park is not on the County page's published community list. Do not assume City or County handling.Confirm with authorityChecked 2026-09-15
Machesney ParkConfirm authority from the building addressAuthority not verifiedConfirm with the community; use the County page to check whether County service appliesBuilding DivisionWinnebago County Community DevelopmentNot published in the reviewed sourceMachesney Park is not on the County page's published community list. Confirm the current permit route before planning work.Confirm with authorityChecked 2026-09-15
Cherry ValleyCommunity listed by the County Building DivisionWinnebago County Community Development, Building DivisionCounty Building Division pageBuilding DivisionWinnebago County Community DevelopmentNot published in the reviewed sourceConfirm the parcel and the complete dock, door, structural, and electrical scope with the County.VerifiedChecked 2026-09-15
New MilfordCommunity listed by the County Building DivisionWinnebago County Community Development, Building DivisionCounty Building Division pageBuilding DivisionWinnebago County Community DevelopmentNot published in the reviewed sourceConfirm whether repair, replacement, or associated work needs County review.VerifiedChecked 2026-09-15
RoscoeCommunity listed by the County Building DivisionWinnebago County Community Development, Building DivisionCounty Building Division pageBuilding DivisionWinnebago County Community DevelopmentNot published in the reviewed sourceUse the facility address and full equipment scope when asking the County what review applies.VerifiedChecked 2026-09-15
RocktonCommunity listed by the County Building DivisionWinnebago County Community Development, Building DivisionCounty Building Division pageBuilding DivisionWinnebago County Community DevelopmentNot published in the reviewed sourceConfirm the authority's treatment of the full project rather than relying on the name of the equipment.VerifiedChecked 2026-09-15
South BeloitCommunity listed by the County Building DivisionWinnebago County Community Development, Building DivisionCounty Building Division pageBuilding DivisionWinnebago County Community DevelopmentNot published in the reviewed sourceConfirm permit and inspection questions for the specific address and proposed scope.VerifiedChecked 2026-09-15
WinnebagoConfirm authority from the building addressAuthority not verifiedConfirm with the community; use the County page to check whether County service appliesBuilding DivisionWinnebago County Community DevelopmentNot published in the reviewed sourceThe Village of Winnebago is not on the County page's published community list. Confirm the current route.Confirm with authorityChecked 2026-09-15
PecatonicaConfirm authority from the building addressAuthority not verifiedConfirm with the community; use the County page to check whether County service appliesBuilding DivisionWinnebago County Community DevelopmentNot published in the reviewed sourcePecatonica is not on the County page's published community list. Confirm the permitting office.Confirm with authorityChecked 2026-09-15
DurandCommunity listed by the County Building DivisionWinnebago County Community Development, Building DivisionCounty Building Division pageBuilding DivisionWinnebago County Community DevelopmentNot published in the reviewed sourceConfirm review for the specific building and all associated work with the County.VerifiedChecked 2026-09-15
Unincorporated Winnebago CountyUnincorporated County addressWinnebago County Community Development, Building DivisionCounty Building Division pageBuilding DivisionWinnebago County Community DevelopmentNot published in the reviewed sourceThe County page expressly lists unincorporated Winnebago County; confirm the parcel and project scope.VerifiedChecked 2026-09-15
BelvidereAddress inside the City of BelvidereCity of Belvidere Building DepartmentCity Building Department pageBuilding DepartmentCity of Belvidere, IllinoisNot published in the reviewed sourceThe City identifies its permitting and inspection role. Ask about the proposed dock or door work.VerifiedChecked 2026-09-15
Poplar GroveConfirm the current building or code-enforcement contactAuthority not verifiedVillage contact pageContact the VillageVillage of Poplar Grove, IllinoisNot published in the reviewed sourceDo not assume Boone County handles Village permits; ask the Village to identify the current office.Source linkedChecked 2026-09-15
CapronConfirm authority from the building addressAuthority not verifiedConfirm directly with the community or Boone CountyContact the VillageVillage of Poplar Grove, IllinoisNot published in the reviewed sourceNo Capron or Boone County permitting office was verified in the reviewed source set. The linked Boone-area municipal contact does not establish jurisdiction.Confirm with authorityNo substantive source check
Unincorporated Boone CountyConfirm authority for the parcelAuthority not verifiedConfirm directly with Boone CountyBuilding DepartmentCity of Belvidere, IllinoisNot published in the reviewed sourceThe linked City page establishes only Belvidere's role and does not establish County jurisdiction. A broader County office was not verified.Confirm with authorityNo substantive source check

Manufacturing statistics by state

For a separate, non-commercial research asset, see the July 2026 manufacturing statistics by state. It includes all 50 states, job-count and employment-share rankings, annual change, methodology checks, source links, and versioned downloads.

High lift vs vertical lift

For a separate, non-commercial comparison of headroom, backroom, lift limits, operators, and source conflicts, see the high lift vs vertical lift headroom data. It includes worked examples, strict comparison tables, source notes, and versioned CSV and JSON downloads.

Illinois layers

Local authority is only one layer of project review. The Illinois Capital Development Board identifies the amended 2024 IECC, effective November 30, 2025, under 71 Ill. Adm. Code 600 as the Illinois Energy Conservation Code. Applicability, exceptions, and project timing are specific to the work; this reference does not state a required door R-value or U-factor and does not claim that the code requires seals.

Illinois review layers to raise for a specific project
LayerWhat the reviewed record supportsProject decisionOfficial source
Energy codeAmended 2024 IECC, effective November 30, 2025, under 71 Ill. Adm. Code 600Confirm applicability, exceptions, and timing for the proposed opening and associated work.Illinois Capital Development Board energy-code page
Prevailing wageNo project-specific applicability statement was verified.Do not treat silence as confirmation that the layer applies or does not apply; obtain project-specific guidance for public work.Not published as a verified claim
Licensing summaryA broader Illinois or local licensing summary has not been verified.Ask the provider for documentation required by the facility and confirm project requirements with the issuing authority.Not published as a verified claim

Technical reference index

This index helps a maintenance manager distinguish documents that may be raised during equipment, safety, or opening-protective review. An entry is not a statement that the document applies to every dock. OSHA regulations are not consensus standards, and OSHA's restraint directive and motor-carrier interpretation are not standalone regulations. Applicability belongs with the employer's responsible safety personnel and the appropriate authority.

Technical references by document type and narrow relevance
DocumentIssuing organizationDocument typeNarrow relevanceOfficial sourceChecked date
29 CFR 1910.26 — DockboardsU.S. Occupational Safety and Health AdministrationregulationDockboard capacity, securing against movement, and placement; a dock plate is not a leveler.29 CFR 1910.26 — Dockboards2026-09-15
29 CFR 1910.28 — Duty to have fall protection and falling object protectionU.S. Occupational Safety and Health AdministrationregulationIndex entry for a facility-specific review of open dock-edge fall exposure; no requirement is paraphrased here.29 CFR 1910.28 — Duty to have fall protection and falling object protectionCatalog only
29 CFR 1910.147 — The control of hazardous energy (lockout/tagout)U.S. Occupational Safety and Health AdministrationregulationHazardous-energy control during machine servicing; not a complete pit-entry procedure.29 CFR 1910.147 — The control of hazardous energy (lockout/tagout)2026-09-15
29 CFR 1910.176 — Handling materials, generalU.S. Occupational Safety and Health AdministrationregulationCatalog entry for aisles, clearances, and storage in materials-handling areas; no requirement is paraphrased here.29 CFR 1910.176 — Handling materials, generalCatalog only
29 CFR 1910.178 — Powered industrial trucksU.S. Occupational Safety and Health AdministrationregulationPowered trucks entering trailers and securing trailers against movement; scope differs from the directive and interpretation.29 CFR 1910.178 — Powered industrial trucks2026-09-15
STD 01-11-007 — Mechanical means of restraint for trailers at loading docksU.S. Occupational Safety and Health Administrationagency directiveEnforcement guidance on mechanical restraints as a means of securing trailers; not a standalone regulation.STD 01-11-007 — Mechanical means of restraint for trailers at loading docks2026-09-15
Standard interpretation, March 7, 2011 — motor carrier / loading dock enforcementU.S. Occupational Safety and Health Administrationagency interpretationEnforcement limits involving motor carriers and loading dock operations; facility applicability remains case-specific.Standard interpretation, March 7, 2011 — motor carrier / loading dock enforcement2026-09-15
ANSI MH30.1 — Performance and Testing of Dock Leveling DevicesANSI / Material Handling Industry (MHI)consensus standardCatalog entry for the industry standard for dock leveling devices; contents were not read or paraphrased.ANSI MH30.1 — Performance and Testing of Dock Leveling DevicesCatalog only
ANSI MH30.3 — Performance and Testing of Vehicle Restraining DevicesANSI / Material Handling Industry (MHI)consensus standardCatalog entry for the industry standard for vehicle restraining devices; contents were not read or paraphrased.ANSI MH30.3 — Performance and Testing of Vehicle Restraining DevicesCatalog only
NFPA 80 — Standard for Fire Doors and Other Opening ProtectivesNational Fire Protection Associationconsensus standardCatalog entry for fire-door inspection, testing, and maintenance; edition, interval, and local adoption are not asserted.NFPA 80 — Standard for Fire Doors and Other Opening ProtectivesCatalog only
UL 325 — Standard for Door, Drapery, Gate, Louver, and Window Operators and SystemsUL Standards & Engagementconsensus standardCatalog entry for the product safety standard for door operators and entrapment protection; contents were not read.UL 325 — Standard for Door, Drapery, Gate, Louver, and Window Operators and SystemsCatalog only
DASMA Technical Data SheetsDoor & Access Systems Manufacturers Associationindustry technical sheetCatalog entry for the trade-association technical sheet library for doors and dock equipment; individual sheets were not read.DASMA Technical Data SheetsCatalog only

Definitions and method

Issuing authority

The government office that accepts, reviews, or directs permit questions for the project address. Shared services can make that a county office even when the mailing address names a village. The directory reports only relationships supported by the reviewed sources.

Same-size replacement

On this page, this phrase refers only to the City of Rockford FAQ's limited door/window replacement language: size unchanged and no required fire rating. It does not decide whether changes to an operator, wiring, framing, leveler, restraint, pit, or other associated work require review.

Fire-rated assembly

An opening protective whose label and function are part of the building's fire-protection approach. This reference does not identify the rating, adopted edition, testing interval, or required service for a particular opening. Preserve labels and confirm the assembly with the authority and a capable provider.

Field-level verification

Confirmation using the actual address, equipment identity, labels, drawings when available, and full proposed scope. Directory status cannot replace this step because municipal boundaries, parcel conditions, and associated work can change the answer.

Index entry vs verified requirement

An index entry records an official title or catalog link and its narrow subject. It does not paraphrase inaccessible text or establish local adoption. A verified substantive requirement is narrower: the linked text was opened and supports the statement made. Even then, project-level applicability is not decided here.

Source selection

The directory favors official city, village, county, state, federal, standards-issuer, and trade-association pages. It does not use contractor pages or competitor summaries to assign jurisdiction or paraphrase standards. Where the reviewed official set did not identify an office, the row says to confirm instead of filling the gap.

Updates

Substantive pages opened during this review carry the date 2026-09-15. “Catalog only” means the official title or directory was indexed but its contents were not read. A null date in the CSV preserves that distinction. Contact routes and authority arrangements should be rechecked before each project.

Limitations

This page is not a permit, code opinion, legal opinion, safety-training program, repair procedure, or project-compliance determination. It does not establish fees, inspection timing, approval, provider credentials, or whether any cited document applies to a specific employer or opening. Agency phone numbers appear only when the number was verified in the reviewed source record; none met that publication rule in this edition.

For planned equipment changes, review the loading dock equipment installation and replacement page. For commercial repair request scope, return to the Rockford loading dock repair homepage.

Directory rows published: 16. Each row keeps its own verification status and checked date.

Need a repair or installation instead of a reference?

Call to describe the commercial equipment, problem, and building address. A third-party provider confirms whether it can help and discusses scope, availability, pricing, and terms directly with you.

Calls to the number on this site may be routed to a third-party loading dock and door service provider for review. The provider — not this website — confirms whether it can take the job, when it can be there, what it will charge, and on what terms. This website does not perform repairs, employ technicians, stock parts, or guarantee that a provider is available.